Last News:
You are here:Home > News and support > Trouble shooting of automatic sliding door
If automatic sliding door opener not working normal, please check the trouble shooting as follow:
Firstly: Power off, use hand manual open and close it. To check if it's the problem of hardware.
1. The hanger is mounted vertically on the leaf.
2. Any friction between the floor guide and the leaf bottom of door leaf.
3. Any friction between the door leaf and frame.
4. Any friction between the hanger and anti-drop device, any friction between the hanger and the rail.
Secondly: If open smoothly, to check if it is the input power problem.
Thirdly: If input power not have problem, please do the following steps:
1. Un-connect all accessories from controller
2. Power on
3. Press testing button
If these steps working, please check the connecting of accessories.
If not working, 1.check the connecting between motor and controller.
2.check the motor
TEL:+8618971265826
Email:autodoorleader@gmail.com
Skype:autodoorleader
Sensor working > open slowly > open fast > slow down > stop > keep opening > close slowly > close fast > slow down > stop
WhatsApp:+8618971265826
Contact Us:
When the automatic sliding door working normal, it will work as follow:
1.Power on, the mechanism start to self-learning. The door will open and close to find the opening and closing position.
2.The mechanism’s working steps are as following:
Vincent Hu
Email:autodoorleader@gmail.com
Skype:autodoorleader
Tel/Wechat:+8618971265826